2021 concrete prices | concrete truck delivery costs (per,ready-mix concrete prices. ready-mix concrete is pre-mixed in batches of 10 cubic yards or more and includes delivery up to 20 miles for $119 to $147 per cubic yard.the quality of ready-mix concrete is much higher than short load delivery because the concrete is precisely prepared at a mixing plant..what are the mix ratios for cement and sand?,below is an example of a sand to cement mix ratio recommendation from a cement manufacturer. concrete - 1 part cement, 2 parts concreting sand and 3 parts 20 millimeter aggregate. mortar - 1 part cement, 4 to 5 parts building sand. alternatively, one can also use 1 part cement, 1 part lime and 4 to 5 parts building sand..

What Can I Do For You?

I accept the Data Protection Declaration
  • Strength of Concrete (PSI) | ProMatcher

    Strength Of Concrete (PSI) | ProMatcher

    the strength of concrete is measure in terms of pounds per square inch (or psi). psi is a measure of compressive strength, or the ability of the material to carry loads and handle compression. 1.) 2500-3000 psi. most concrete has a psi rating of 2500 to 3000. this type of concrete can be used for sidewalks and residential driveways.

  • Actual Concrete Mix Ratios For 3000, 3500, 4000, and 4500

    Actual Concrete Mix Ratios For 3000, 3500, 4000, And 4500

    there are 94 pounds of cement in a 'sack or bag' of cement. that means 3500 psi concrete is called a 6 sack mix or 6 bag mix of concrete. (#'s are rounded off). what is the concrete mix ratio of 25mpa concrete? 25 mpa concrete is equivalent to a 3500 psi concrete mix. so the mix ratio is the same as above: 1 part cement; 3 parts stone; 2.5 parts sand

  • Concrete Mix Ratio And Slump Value Of Concrete

    Concrete Mix Ratio And Slump Value Of Concrete

    psi: standard grade of concrete: m25: 1: 1: 2: 25 mpa: 3625 psi: m30: design mix: 30 mpa: 4350 psi: m35: design mix: 35 mpa: 5075 psi: m40: design mix: 40 mpa: 5800 psi: m45: design mix: 45

  • Ready Mix Concrete Ordering Tips

    Ready Mix Concrete Ordering Tips

    one of the most important factors before ordering ready-mix concrete is knowing the required compressive strength. typically, reinforced concrete ranging between 3,500 to 4,000 psi is used on footing and slabs on grade; between 3,500 to 5,000 psi on suspended slabs, beams and girders; and walls and columns normally require between 3,000 to 5,000 psi.

  • Concrete Mix Ratio: What Is It? What Is 1-2-3? ...And More

    Concrete Mix Ratio: What Is It? What Is 1-2-3? ...And More

    as such, it is worth your time to consult with a concrete professional when you are planning a project that requires a precise amount of concrete strength. 3,000 psi concrete mix ratio. though it is on the lower end of the concrete strength scale, this mix ratio

  • Everything You Need to Know About Concrete Strength | Cor-Tuf

    Everything You Need To Know About Concrete Strength | Cor-Tuf

    the ideal concrete psi for a given project depends on various factors, but the bare minimum for any project usually starts around 2,500 to 3,000 psi. each concrete structure has a normally acceptable psi range. concrete footings and slabs on grade typically require a concrete of 3,500 to 4,000 psi. suspended slabs, beams, and girders (as often found in bridges) require 3,500 to 5,000 psi.

  • Concrete — Lawrence Ready

    Concrete — Lawrence Ready

    standard ready mix concrete is a popular choice for many projects due to its versatility. because of its ability to be delivered in a plastic state, it can be placed by pumping, conveyor, buggie or chute, minimizing the impact of delivery to a project. it can also be formed into any shape at strengths up to 14,000 psi.

  • Avoid too Much Pressure in Concrete | For Construction Pros

    Avoid Too Much Pressure In Concrete | For Construction Pros

    the aci 347-04 equations are based on concrete having a slump of 7 inches or less and placed with a normal vibration to a depth of 4 feet or less.

  • Curing of Cement Concrete - Time and Duration - Concrete

    Curing Of Cement Concrete - Time And Duration - Concrete

    the evaporation rate is influenced by wind, radiant energy from sunshine, concrete temperature, climatic conditions, relative humidity. the evaporation of moisture is driven by the difference in vapor pressure on the concrete surface and the surrounding air. when the difference is high, the evaporation rate is high.

  • 900 CONCRETE (3000 psi)

    900 CONCRETE (3000 Psi)

    iv. ready-mix concrete the 3000 psi design mix and testing results, from the batch plant will be supplied to the engineer for approval upon request or as shown on the “practice requirements” sheet. when ready-mixed concrete is furnished, the supplier will provide the owner a delivery ticket that shows:

  • High-Strength Concrete - Cement

    High-Strength Concrete - Cement

    in the early 1970s, experts predicted that the practical limit of ready-mixed concrete would be unlikely to exceed a compressive strength greater than 11,000 pounds square inch (psi). over the past two decades, the development of high-strength concrete has enabled builders to easily meet and surpass this estimate.

  • Concrete Mix Ratios (Cement, Sand, Gravel)

    Concrete Mix Ratios (Cement, Sand, Gravel)

    preparing the right mix. depending on the application concrete mix design can be complex. the below table gives a basic indication of the mix ratios used for different purposes but should be used as a guide only. some additional things to consider when finding a suitable mix design include but are in no way limited to the following:

  • Concrete Mix Ratio and How to Mix Concrete Including a

    Concrete Mix Ratio And How To Mix Concrete Including A

    to test a concrete mix a 300mm high cone made of steel is used that features a top opening of 100mm diameter and a bottom opening of 200mm diameter. the mixed concrete is placed into the cone through the top, a bar is used to compact the concrete and remove any air

  • Different Types of Concrete Grades and their uses | Base

    Different Types Of Concrete Grades And Their Uses | Base

    different types of concrete grades and their uses. whether you are looking for the right domestic or commercial concrete mix for your construction job, or are just curious about the different grades of concrete and would like to know more, read on to get an understanding of these different types of concrete and their uses, or get in contact today by calling us on 01442 389105

  • Understanding Minimum Specified Compressive ... - Concrete

    Understanding Minimum Specified Compressive ... - Concrete

    if i was an engineer responsible for durable concrete for my project, i would specify: minimum 28-day compressive strength, f’c = 3500 psi o this keeps mix designs submitted to moderate cement content, typically 3500 psi concrete has 564 lbs of cement. the higher the specified strength the more cement

  • Large Concrete Blocks | Standard & Decorative | Ozinga

    Large Concrete Blocks | Standard & Decorative | Ozinga

    our concrete blocks are made from recycled concrete which holds a strength rating of 3,000 – 4,000 psi. their strength and various size options make them perfect for permanent or temporary outdoor solutions for restaurants, special events, job sites and so much more.

  • Investigation of setting time and compressive strength of

    Investigation Of Setting Time And Compressive Strength Of

    1. background. waste concrete is a problem for the concrete manufacturing industry. the term used to define unused concrete that is returned to a facility inside a truck is leftover, and of this, 60% goes directly to a dump, while only 40% is used to produce other concrete blocks or recycled products .ready-mixed concrete, on the other hand, is the fresh concrete produced for delivery to

  • Testing the Compressive Strength of Concrete — What, why

    Testing The Compressive Strength Of Concrete — What, Why

    historical strength test records are used by the concrete producer to establish the target average strength of concrete mixtures for future work. how to test the strength of concrete cylindrical specimens for acceptance testing should be 6 x 12 inch (150 x 300 mm) size or 4 x 8 inch (100 x 200 mm) when specified.

  • Polecat Ready Mix Concrete Supply Company

    Polecat Ready Mix Concrete Supply Company

    standard concrete mix. 1500-6000 psi footer mix, pea gravel mix, curb mix. repeat users of polecat concrete have come to appreciate the following advantages they have with our system: - you only need to rough estimate what you need, as you only pay for what you actually use to the closest ¼ cubic yard. especially important when pouring footers.

  • Products – Nicolia Ready

    Products – Nicolia Ready

    4 x 4 concrete (4000 psi in four hours, quickset) heavyweight concrete (iron-ore aggregates) lightweight concrete. fly ash mix designs to fulfill specifications for leed projects. silica blended cement (a concrete densifier for high strength and heavy-duty applications) state and county approved flowable-fill concrete.

  • HY-TEC Concrete and Calculator

    HY-TEC Concrete And Calculator

    a default slump of 100 mm has been adopted by the premix concrete industry to reduce the uncontrolled addition of water on site and make placing and compacting of concrete easier for concreters. 32 mpa, 40 mpa, 50 mpa. higher strength is commonly used for concrete that will

  • ACI Concrete Terminology

    ACI Concrete Terminology

    1 aci concrete terminology a/f ratio — the molar or mass ratio of aluminum oxide (al 2o 3) to iron oxide (fe 2o 3), as in portland cement. abrams’ law — a rule stating that, with given concrete materials and conditions of test, the ratio of the amount of water to the amount of the cement in the mixture

  • Importance of Water-Cement Ratio in Concrete

    Importance Of Water-Cement Ratio In Concrete

    example, having 0.4 water-cement ratio gives 5600 psi (pound-force per square inches) or 394 kg/cm 2 (kilogram-force per square centimeter) compressive strength whereas 0.7 water/cement ratio reduces compressive strength up to 1067 psi or 75 kg/cm 2 or even less provided allow other factors are constant.

  • GROUT FOR CONCRETE MASONRY - NCMA

    GROUT FOR CONCRETE MASONRY - NCMA

    when using the strength design provisions of the building code requirements for masonry structures (ref. 8), a maximum specified grout compressive strength of 5,000 psi (34.47 mpa) for concrete masonry construction is applied.